Insulation Resistance Tester
Insulation Resistance Tester

Insulation Resistance Tester

MOQ : 100 Pieces

Insulation Resistance Tester Specification

  • Display Type
  • Digital LCD
  • Number of Specimens
  • 1
  • Operating Voltage
  • Battery powered/AC mains
  • Power Supply
  • AC 220V, 50/60 Hz
  • Equipment Type
  • Digital Insulation Resistance Tester
  • Automation Grade
  • Manual
  • Resolution
  • 0.01 M
  • Interface Type
  • Test lead connectors
  • Mounting Type
  • Portable, handheld
  • Features
  • Auto power off, Overload protection, Data hold
  • Port Size
  • Standard input terminals
  • Measuring Range
  • 250V/500V/1000V selectable; resistance: 0.1 M to 2000 M
  • Accuracy
  • 5% of reading
  • Frequency
  • 50/60 Hz
  • Temperature
  • 0C to 40C
  • Application
  • Electrical maintenance, cable and insulation testing
  • Response Time
  • <2 seconds
  • Specimen Size
  • Standard electrical insulation sizes
  • Test Range
  • 0.1 M to 2000 M
  • Humidity
  • 35% to 85% RH
  • Usage
  • Testing insulation resistance
  • Capacity
  • Continuous/Intermittent duty
  • Machine Weight
  • Approx. 1.5 kg
  • Test Speed
  • Manual
  • Test Width
  • Standard single channel
  • Test Stroke
  • Fixed; insulation resistance measurement only
  • Control Mode
  • Push-button
  • Lead Length
  • Standard 1 m
  • Case Material
  • ABS Plastic
  • Test Voltage Options
  • 250V, 500V, 1000V
  • Dimensions
  • 180 x 130 x 80 mm
  • Sampling Time
  • 1 second
  • Continuity Test
  • Available
  • Safety Category
  • CAT III 1000V
  • Fuse Protection
  • Yes
  • Battery Type
  • AA batteries, x6
  • Protection Class
  • IP40
  • Data Storage
  • No
  • Overload Indication
  • Yes
  • Backlight
  • LCD backlight
 
 

About Insulation Resistance Tester

Being a prominent firm, we are distributing a wide array of Insulation Resistance Tester. It is well known for its easy operation, great stability and light in weight. This tester is used to measure the voltage and ohmic value. Other than that, provided tester is also beneficial to work on generators, electrical cables, panels, switch gears etc. Insulation Resistance Tester is safe and simple to use. It is made in accordance to meet the international and domestic quality standards.



Versatile Voltage and Accurate Measurement

With selectable test voltages of 250V, 500V, and 1000V, this insulation resistance tester adeptly handles a broad spectrum of electrical applications. The measuring range of 0.1 M to 2000 M, coupled with 5% accuracy and 0.01 M resolution, ensures precision during cable and equipment diagnostics, enhancing reliability during both field and laboratory settings.


Designed for Safety and Ease of Use

Safety is prioritized with a CAT III 1000V safety rating, fuse protection, overload indication, and an ABS plastic case. The tester supports manual operation with user-friendly push-buttons, an LCD backlight for visibility, and clear readouts. Its powered by six AA batteries or AC 220V mains, featuring auto power off and data hold functions for additional workflow convenience.


Robust and Portable for On-Site Testing

Engineered for portability, the testers ergonomic design allows for handheld operation. A protective IP40 rating and standard 1-meter test leads make it suitable for on-site electrical maintenance. Built for durability, it accommodates a variety of environments with operating temperatures from 0C to 40C and 35%85% RH humidity. Continuous or intermittent testing is supported.

FAQs of Insulation Resistance Tester:


Q: How do I select the test voltage on this insulation resistance tester?

A: The tester allows you to choose from 250V, 500V, and 1000V test voltages using the control push-buttons on its interface. Select the appropriate voltage based on your specific testing requirement for accurate insulation assessment.

Q: What types of electrical tests can this device perform?

A: This tester is designed for insulation resistance measurements and continuity tests. It offers accurate readings for insulation quality and helps detect faults or degradation in cables and electrical installations.

Q: When should I use the data hold and auto power off features?

A: The data hold function is useful when you need to temporarily freeze the displayed value for reference or recording, whereas the auto power off feature conserves battery life by switching off the device during periods of inactivity.

Q: Where can this tester be used safely?

A: With its CAT III 1000V safety rating, the tester is suitable for use in industrial, commercial, and residential electrical environments, including distribution panels, cable installations, and equipment maintenance, provided operating conditions (0C40C, 35%85% RH) are met.

Q: What is the correct process to measure insulation resistance?

A: First, ensure the equipment under test is powered off and safely disconnected. Connect the test leads to the device and the specimen, select the desired test voltage, and press the start button. The digital LCD will display results within 12 seconds.

Q: How does overload protection benefit the user?

A: Overload indication and built-in fuse protection help safeguard both the user and the instrument against accidental over-current or voltage surges, ensuring secure testing in demanding field conditions.

Q: What is the advantage of the testers portable design?

A: The lightweight, handheld construction with standard input terminals and durable ABS housing allows technicians to easily transport and operate the device on-site or in confined spaces, making it ideal for everyday fieldwork.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail